Show simple item record

Valores normales de la amplitud de acomodación subjetiva entre los 5 y los 19 años de edad

dc.creatorLeón Álvarez, Alejandrospa
dc.creatorEstrada Álvarez, Jorge Mariospa
dc.creatorMedrano, Sandra Milenaspa
dc.date2014-12-03spa
dc.date.accessioned2017-06-12T20:10:30Zspa
dc.date.available2017-06-12T20:10:30Zspa
dc.identifierhttp://revistas.lasalle.edu.co/index.php/sv/article/view/3290spa
dc.identifier10.19052/sv.3290spa
dc.identifier.urihttp://hdl.handle.net/10185/19510
dc.description.abstractObjective: To determine the normative values of the amplitude of accommodation (AA) with four subjective procedures. Materials and methods: 586 students between the ages of 5 and 19 from public schools in Pereira were included. AA was measured by means of the Donders (push up [PU], push down [PD] and modified push down [MPD]) and Sheard (minus lens [ML]) methods. Results: The average for the entire age group was: PU: 14.58 D; PD: 9.55 D; MPD: 12.01 D; ML: 11.00 D; in addition, the change of the AA for age was estimated through linear regression: PU: 0.25 D; PD: 0.03 D; MPD: 0.10 D; ML: 0.09 D. Conclusions: AA is different with each technique, and when compared to studies conducted outside of Colombia; furthermore, AA decrease is not similar in these tests.spa
dc.description.abstractObjetivo: determinar los valores normativos de la amplitud de acomodación (AA) con cuatro procedimientos subjetivos. Materiales y métodos: fueron incluidos 586 estudiantes entre 5 y 19 años de edad, pertenecientes a los colegios públicos de Pereira, a los cuales se les midió la AA a través de los métodos de Donders (push up [PU], push down [PD] y modified push down [MPD]) y de Sheard (minus lens [ML]). Resultados: la mediana por técnica de todo el grupo etario fue: PU: 14,58 D; PD: 9,55 D; MPD: 12,01 D; ML: 11,00 D; adicionalmente, mediante una regresión lineal, se estimó el cambio de la AA respecto a la edad: PU: 0,25 D; PD: 0,03 D; MPD: 0,10 D; ML: 0,09 D. Conclusiones: la AA con cada técnica es diferente, así como al ser comparada con estudios realizados fuera de Colombia; además, la disminución de la AA no es similar en estas pruebas.spa
dc.formatapplication/pdfspa
dc.languagespaspa
dc.publisherUniversidad de La Salle. Revistas. Ciencia y Tecnología para la Salud Visual y Ocular.spa
dc.relationhttp://revistas.lasalle.edu.co/index.php/sv/article/view/3290/2628spa
dc.relation/*ref*/Anderson, H. A., Glasser, A., Stuebing, K. K. y Manny, R. E. (2009). Minus lens stimulated accommodative lag as a function of age. Optom. Vis. Sci., 86(6), 685-694.spa
dc.relation/*ref*/Anderson, H. A., Hentz, G., Glasser, A., Stuebing, K. K. y Manny, R. E. (2008). Minus-lens-stimulated accommodative amplitude decreases sigmoidally with age: a study of objectively measured accommodative amplitudes from age 3. Invest. Ophthalmol. Vis. Sci., 49(7), 2919-2926.spa
dc.relation/*ref*/Antona, B., Sánchez, I., Barrio, A. Barra, F. y González, E. (2009). Intra-examiner repeatability and agreement in accommodative response measurements. Ophthalmic Physiol. Opt., 29(6), 606-614.spa
dc.relation/*ref*/Asamblea Médica Mundial (1964). Human experimentation: code of ethics of the world medical association (Declaration of Helsinki) (1964). Can. Med. Assoc. J., 91(11), 619.spa
dc.relation/*ref*/Benjamin, W. J. y Borish, I. M. (2006). Borish’s clinical refraction (2.a ed.). San Luis, Estados Unidos: Butterworth Heinemann y Elsevier.spa
dc.relation/*ref*/Benzoni, J. A. y Rosenfield, M. (2012). Clinical amplitude of accommodation in children between 5 and 10 years of age. Optom. Vis. Dev., 43(3), 109-114.spa
dc.relation/*ref*/Buitrago, D., Flórez, A. y Merchán, L. (2008). Evaluación de la reproducibilidad de los métodos de Sheard y Donders para determinar la amplitud de acomodación en personas de 10 a 39 años de edad en el departamento de Quindío. Ustasalud Optometría, 7, 5-9. Recuperado de http://200.21.227.151/inicio/publicaciones/div_salud/pdf/ustaopto_7.pdfspa
dc.relation/*ref*/Chen, A.-H. y O’Leary, A. (1998). Validity and repeatability of the modified push-up method for measuring the amplitude of accommodation. Clinical and Experimental Optometry, 81(2), 63-71. Doi:10.1111/j.1444-0938.1998.tb06628.xspa
dc.relation/*ref*/Edwards, M. H., Law, L. F., Lee, C. M., Leung, K. M. y Lui, W. O. (1993). Clinical norms for amplitude of accommodation in Chinese. Ophthalmic Physiol Opt, 13(2), 199-204.spa
dc.relation/*ref*/Elliott, D. B., Yang, K. C. y Whitaker, D. (1995). Visual acuity changes throughout adulthood in normal, healthy eyes: seeing beyond 6/6. Optom. Vis. Sci., 72(3), 186-191.spa
dc.relation/*ref*/Hofstetter, H. W. (1944). A comparison of Duane’s and Donders’ tables of the amplitude of accommodation. Am. J. Optom. and Arch. Am. Acad. Optom., 21(9), 345-363.spa
dc.relation/*ref*/Iyamu, E., Iyamu, J. E. y Oghovwerha, L. (2012). Anthropometry, amplitude of accommodation, and spherical equivalent refractive error in a nigerian population. ISRN Ophthalmol, 2012, 295613.spa
dc.relation/*ref*/Kragha, I. K. (1986). Amplitude of accommodation: population and methodological differences. Ophthalmic. Physiol. Opt., 6(1), 75-80.spa
dc.relation/*ref*/Koslowe, K., Glassman, T., Tzanani-Levi, C. y Shneor, E. (2010). Accommodative amplitude determination: pull-away versus push-up method. Optom. Vis. Dev., 41(1), 28-32.spa
dc.relation/*ref*/León, A. A. y Medrano, S. (2008). Amplitud de acomodación en la población de Santa Fe de Bogotá, D.C. Ciencia & Tecnología para la Salud Visual y Ocular, 11, 9-14.spa
dc.relation/*ref*/León , A. A., Álvarez, J. M., Lizcano, K. C. y Guzmán, J. L. (2010). Concordancia de las técnicas subjetivas que miden la amplitud de acomodación. Ciencia & Tecnología para la Salud Visual y Ocular, 8(1), 41-52.spa
dc.relation/*ref*/León, A. A., Medrano, S. M. y Rosenfield, M. (2012). A comparison of the reliability of dynamic retinoscopy and subjective measurements of amplitude of accommodation. Ophthalmic. Physiol. Opt., 32(2), 133-141.spa
dc.relation/*ref*/Lyon, D. W., Goss, D. A., Horner, D., Downey, J. P. y Rainey, B. (2005). Normative data for modified Thorington phorias and prism bar vergences from the Benton-IU study. Optometry, 76(10), 593-599.spa
dc.relation/*ref*/Maples, W. C. y Hoenes, R. (2007). Near point of convergence norms measured in elementary school children. Optom. Vis. Sci., 84(3), 224-228.spa
dc.relation/*ref*/McClelland, J. F. y Saunders, K. J. (2004). Accommodative lag using dynamic retinoscopy: age norms for schoolage children. Optom. Vis. Sci., 81(12), 929-933.spa
dc.relation/*ref*/Ministerio de Salud de Colombia (1993). Resolución 008430 de 1993, por la cual se establecen las normas científicas, técnicas y administrativas para la investigación en salud. Bogotá: Autor.spa
dc.relation/*ref*/Ovenseri-Ogbomo, G. O., Kudjawu, E. P., Kio, F. E. y Abu, E. K. (2010). Investigation of amplitude of accommodation among Ghanaian school children. Clin. Exp. Optom., 95(2), 187-191.spa
dc.relation/*ref*/Pagano, M. y Gauvreau, K. (2000). Principles of biostatistics (2.a ed.). Pacific Grove, Estados Unidos: Duxbury.spa
dc.relation/*ref*/Pang, Y., Gabriel, H., Frantz, K. A. y Saeed, F. (2010). A prospective study of different test targets for the near point of convergence. Ophthalmic. Physiol. Opt., 30(3), 298-303.spa
dc.relation/*ref*/Pilar Cacho, M. et al. (1999). Comparison between MEM and nott dynamic retinoscopy. Optometry & Vision Science, 76(9), 650-655.spa
dc.relation/*ref*/Rabbetts, R., B. (2007). Bennett & Rabbett’s Clinical Visual Optics (3.ª ed.). Edimburgo: Butterworth Heinemann Elseiver.spa
dc.relation/*ref*/Rosenfield, M. y Cohen, A. S. (1996). Repeatability of clinical measurements of the amplitude of accommodation. Ophthalmic. Physiol. Opt., 16(3), 247-249.spa
dc.relation/*ref*/Rosenfield, M., Logan, N. y Edwards, K. H. (2009). Optometry: science, techniques and clinical management. Londres: Elsevier Health Sciences.spa
dc.relation/*ref*/Rouse, M. W., Deland, P. N., Chous, R. y Determan, T. F. (1989). Monocular accommodative facility testing reliability. Optom. Vis. Sci., 66(2), 72-77.spa
dc.relation/*ref*/Silva, L., C. (2000). Diseño razonado de muestras y captación de datos en investigación sanitaria. Madrid: Díaz de Santos.spa
dc.relation/*ref*/Somers. B., Gellerstedt, M. y Sjortrom, A. (2004) The Amplitude of of ocular amplitude of accommodation. Am. J. Optm. Physiol. Opt., 60(11), 920-924.spa
dc.relation/*ref*/Somers, W. y Ford, C. (1983). Effect of relative distance magnification on the monocular amplitude of accommodation. Am J Optom Physiol Opt, 60(11), 920-924.spa
dc.relation/*ref*/Sterner, B., Gellerstedt, M. y Sjostrom, A. (2004). The amplitude of accommodation in 6-10-year-old children - not as good as expected. Ophthalmic Physiol Opt, 24(3), 246-251.spa
dc.relation/*ref*/Tassinari, J. (2000). Comparison between MEM and Nott dynamic retinoscopy. Optom. Vis. Sci., 77(3), 119-120.spa
dc.relation/*ref*/Taub, M., Shallo-Hoffmann, J. (2012). Comparison of three clinical tests of accommodation amplitude to hofstetter’s norms to guide diagnosis and treatment. Optom Vis Dev, 43(4), 180-190.spa
dc.relation/*ref*/Ward, P. A. (1987). The effect of spatial frequency on steady-state accommodation. Ophthalmic Physiol. Opt., 7(3), 211-217.spa
dc.relation/*ref*/Win-Hall, D. M. y Glasser, A. (2008). Objective accommodation measurements in prepresbyopic eyes using an autorefractor and an aberrometer. J Cataract Refract Surg, 34(5), 774-784.spa
dc.relation/*ref*/Wold, J. E., Hu, A., Chen, S. y Glasser, A. (2003). Subjective and objective measurement of human accommodative amplitude. J Cataract Refract Surg, 29(10), 1878-1888.spa
dc.rightsCopyright (c) 2016 Universidad de La Sallespa
dc.rightshttps://creativecommons.org/licenses/by-nc/4.0/deed.esspa
dc.subjectAmplitude of accommodation; push up; push down; modified push down; minus lens; donders; sheard; normal values.spa
dc.subjectAmplitud de acomodación; push up; push down; modified push down; minus lens; donders; sheard; valores normales.spa
dc.titleNormal Values of Amplitude of Subjective Accommodation between the Ages of 5 and 19spa
dc.titleValores normales de la amplitud de acomodación subjetiva entre los 5 y los 19 años de edadspa
dc.typeinfo:eu-repo/semantics/articlespa
dc.typeinfo:eu-repo/semantics/publishedVersionspa
dc.rights.licensehttp://creativecommons.org/licenses/by-nc-nd/4.0/spa


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record